31
Bosch Security Systems 09/07 BLCC500R FTR1.02
Solution 16 i
Quick Start Guide
Copyright © 2007
E&OE
Test RF Device
MENU 3-3-2
Inputs > Global Input Options >
EOL Value
MENU 3-4-0
0 = No EOL
5
1 = 1K0
6 = 4K7
11 = 6K8 Alarm with 2K2 Tamper
2 = 1K5
7 = 5K6
12 = 10K Alarm with 10K Tamper
3 = 2K2
8 = 6K8
13 = 22K
4 = 2K7
9 = 8K1
14 = 3K3 with 6K8 Tamper
5 = 3K3
10 = 10K
15 = Split EOL (Parallel)
(3K3 = Primary 6K8 = Secondary)
Enter 0 - 15 Then Press [OK] To Program Globally The EOL Resistor For
All Zones.
(*** System Wide Parameter ***)
Inputs > Global Input Options >
Keyswitch Options
MENU 3-4-1
0
= Latching - All On/Off
5 =
Momentary All On/Off
0
1 =
Latching - All On
6 =
Momentary - All On
2 =
Latching Part On/Off
7 =
Momentary - Part
On/Off
3 =
Latching - Part On
8 =
Momentary - Part On
4 =
Latching Off
9 =
Momentary - Off
Enter 0 - 9 Then Press [OK] To Program How The Keyswitch Will
Operate.
(*** System Wide Parameter ***)
Zone Default Table
��� ����� ����� ���� ��� ������� ������ ��� ��� ���� ���������� �� ��� �������� ���� �� �������� ����� � �� �� ��� ��� �� �������
������ ����� ������ �� ��� ���� �� ��� ������� ��� ��������� �� �� fi�����
����������� ������
���� �
���� �
���� �
���� �
����� � �� ��
Zone Name
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5 - Zone 16
Zone Type
1 = Delay 1
5 = Handover
5 = Handover
5 = Handover
3 = Instant
Area Assignment
1
1
1
1
1
Pulse Count
0
0
0
0
0
Pulse Count Time (Sec’s)
120
120
120
120
120
Access Group
0
0
0
0
0
Report Route
2
2
2
2
2
Reporting Options
Lockout Dialler
Y
Y
Y
Y
Y
Report Alarm
Y
Y
Y
Y
Y
Report Alarm Restore
Y
Y
Y
Y
Y
Report Trouble
Y
Y
Y
Y
Y
Report Trouble Restore
Y
Y
Y
Y
Y
Report Bypass
Y
Y
Y
Y
Y
Report Bypass Restore
Y
Y
Y
Y
Y
Delay Report
N
N
N
N
N
Zone Options
Lockout Siren
Y
Y
Y
Y
Y
Silent Alarm
N
N
N
N
N
Inverted Seal
N
N
N
N
N
Bypass Allowed
Y
Y
Y
Y
Y
Sensor Watch
N
N
N
N
N
Armed When Part On
Y
Y
Y
Y
Y
Reserved
N
N
N
N
N
Test On Exit
N
Y
Y
Y
Y
Table 19: Zone Defaults
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1
Tamper On Short
N
2
Reserved
N
3
Response Time 500ms
N
4
Reserved
N
5
Keyswitch Open / Close Report
Y
6
Alarm On Tamper
N
7
Reserved
N
8
Reserved
N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
(*** System Wide Parameter ***)
Inputs > PGM Input >
Input Type
MENU 3-5-0
0 =
Disabled
0
1 =
Latching - On/Off (RF Relay)
2 =
Momentary - On/Off (RF Relay)
3 =
Digiflex RF On/Off
6 =
Ness Serial RF Receiver
4 =
Bosch Serial RF Receiver
7 =
Inovonics Serial Receiver
5 =
Reserved
8 =
Secure Wireless Receiver
Enter 0 - 7 + [OK] to select the interface method used for the given RF
receiver.