4.7
Water inlet / condensation system
The time-fill water inlet system lies next to the left side of the
tank. It doesn’t fill water into the bottom of the tank through the
sump, but into the left side of the tank, near the bottom.
A vent on the left side of the tank aids water flow and allows
condensation to exit during drying.
There are two hoses connected to the water inlet system, the
water inlet hose (from the water supply hose) and drain hose.
The total drain hose length is 92” (~ 7.67’), including the portion
inside the dishwasher.
4.7.1
Water inlet valve
A plastic mounting bracket secures the hot water inlet valve on
the rear of the base. A hot water supply hose is supplied with
dishwashers and threaded onto the inlet valve.
Inlet valves have a flow limiter to keep the incoming water
pressure to specified levels, regardless of the water supply
pressure.
1
2
1. Water inlet (to tank)
2. Vent (to tank)
1. Inlet filter
2. Hose coupling
3. Supply hose
4. Mounting bracket
5. Terminal
6. Coil (solenoid)
7. Seal
8. Flow limiter
9. Inlet hose (to dw)