Diagnostics
8–1
1070 066 091-102 (01.08) GB
8
Diagnostics
8.1
Drive configuration / logbook
You will be shown
static
information on:
D
software version (firmware version)
D
module and motor type
D
current DSS mode (in the ”DSS Master” area)
D
application
D
interface type and version
D
DSS errors
D
Diagnostics class 1 errors
L
Start the configuration display with
D
menu options DIAGNOSTICS
"
MODULE CONFIGURATION, – or –
D
"
MODULE CONFIGURATION in the ”Overview” window.
L
Do not perform any operations (mouse click, keyboard entry, etc.) before the
module configuration display appears. The DSS will only read the necessary
information from the drive when the module configuration display is called
up.
Example of the configuration display for a drive with an analog interface:
(1)
Logbook
In the ”Logbook” area, you may display the last 16 ”DSS errors” and ”Class 1
errors” at any time.
DSS errors:
communication errors between the DSS and the drive.
The error list contains the parameter number that experi-
enced the error during transmission, as well as the corre-
sponding error code.
To display the error in plain text, click on (1) and then press
<F1>.
Class 1 errors: Contents of parameter S-0-0129 (Manufacturer’s Class 1)
and S-0-0011 (Diagnostics class-1) are shown as hexadeci-
mal values. Every high bit is assigned a certain error (cf.
”Servodyn-D parameter description” manual).
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01