Initial commissioning
5–10
1070 066 091-102 (01.08) GB
5.3
Save all parameter settings (data backup)
It is urgently recommended to backup all relevant data when the parameters
for a drive have been set.
This data backup will be required to
D
efficiently perform series commissioning
D
restore a precisely defined drive status (e.g. after a parameter loss, firm-
ware update or hardware replacement)
D
document all parameters used for a drive.
L
Make sure that
no
drive enable command has been given.
L
Select the menu sequence:
FILE
"
IDN BACKUP
Enter a new file name. The drive is switched to phase 4, then reads all pa-
rameters stored in the FEPROM and saves them in the previously specified
file. An exception are driver files and the data of the electronic rating plate.
L
Create a suitable directory structure on the hard disk drive of your PC to
which you can copy all parameter files of the drive.
For example, you could establish a hierarchy that adequately represents in-
dividual machine types including their feed, auxiliary and spindle axes.
L
Copy all files to a removable data carrier. Store this data carrier in a safe
place.
.
In order to transfer the backup back to the drive, if necessary, load the
file into the DSS editor, click on the ”Automatic” radio button and then
select ”Set” (cf. section 4.3).
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01