102
en | Troubleshooting transponders, points, receivers, and alert units
Security Escort
2017.08 | V2.18.1.0 | DOC
Training Manual
Robert Bosch (SEA) Pte Ltd
Symptoms
Probable Cause
Possible Solutions
Communication failures from
all transponders.
Loss of power.
Check power to Moxa/
Lantronix device.
Cable from Moxa device to
transponder.
Must use standard 9 pin
female to 9 pin male cable.
Cable from Lantronix device
to transponder.
Must use modified 25 pin
male to 9 pin male cable.
Refer to the Lantronix wiring
notes.
Moxa/Lantronix device might
not be running.
Unplug power to Moxa/
Lantronix device and plug
back in to restart Moxa/
Lantronix device.
Cable from Moxa/Lantronix
device to Ethernet network.
Check Ethernet cable
between Moxa/Lantronix
device and Ethernet network.
Replace if cable is bad.
Tab. 7.6:
Transponder communication with Moxa/Lantronix device
7.3.4
EA500 transponder bus faults