26/52 Installation
Bosch Rexroth AG
, VT-MRMA1-1, RE 30214-B/03.2019
7.3 Recommended accessories
We recommend the use of the following accessories for connecting the amplifier
module VT-MRMA1. These accessories are not included in the scope of delivery, but
can be ordered separately from Bosch Rexroth:
Table 25: Accessories
Component
Material number
Compact power supply unit VT-NE30-2X
R901082348
7.4 Installing the VT-MRMA1
▶
For mounting, observe the notes on applicable standards and operating
conditions in the data sheet.
▶
Open and wire the amplifier module only when it is disconnected from the power
supply.
▶
Do not lay solenoid or signal cables near power cables!
▶
Generally, route all electrical connection cables via strain reliefs.
▶
Use shielded cables (suitable for EMC) for signal and valve cables.
▶
Use relays with gold-plated contacts for switching command values (small
voltages, small currents).
▶
Do not use any silicone-containing sealants, adhesives or insulating agents.
▶
See to it that the installation position provides ease of maintenance, i.e.
unhindered access to connection lines. Ensure free access to the connection
side. The cable ends should be sufficiently long in order that the amplifier can
also be removed from the DIN rail when connected.
▶
Before installing the device, note the details given on the nameplate. If
nameplates are no longer visible or legible after installation you will have the data
at hand at any time.
▶
When several modules are installed, see to it that there is sufficient space to
remove the analog amplifier modules again.
The installation position of the analog amplifier module is vertical. The amplifier
module can be installed without tools on a mounting rail TH35-7.5 to EN 60715 (DIN
rail). Latches with spring are provided for fixation of the module housing.
By snapping the housing of the VT-MRMA1 on a conductive mounting rail, the ground
connection is established. This constitutes the HF grounding of the analog amplifier
modules VT-MRMA1.
▶
Let the amplifier module snap in on the mounting rail. The latch (with spring
pressure) prevents loosening of the module housing from the mounting rail.
▶
To loosen the module, push the latch downwards.
Содержание Rexroth VT-MRMA1-1
Страница 1: ...Operating instructions RE 30214 B 03 2019 Replaces 03 2017 English VT MRMA1 1 Analog amplifier module ...
Страница 50: ...50 52 Alphabetical index Bosch Rexroth AG VT MRMA1 1 RE 30214 B 03 2019 ...
Страница 51: ...Alphabetical index 51 52 RE 30214 B 03 2019 VT MRMA1 1 Bosch Rexroth AG ...