3 608 878 300
Tightening Technology |
Bosch Rexroth AG 623
System 350
| 3 608 878 300/2019-03
Table 7–40:
Barcode scanner within ErgoSpin: Timing parameter
Timing
parameter
Explanation
Standard value
[s]
Value range [s]
Modification
step [s]
Special value [s]
Activation time
laser
Maximum
illumination time
until automatic
deactivation of the
laser
–
0,5…25,5
0,1
0: Continuous
operation
Release time
The scanner can
be released using
the PLC signal
EnScan
. The
duration is set
using this
parameter.
–
1…99
1
0: Scanner is
released as long
is the PLC-signal
is present.
1…99 If the
PLC-signal is
present, the
scanner is
released from the
set time.
Time acoustic
signal decode
Duration of the
acoustic signal
upon recognizing
a barcode
–
0,1…9,9
0,1
Delay during
continuous
operation
Only relevant if
scanner in
continuous
operation (laser
always activated)
Waiting time upon
recognizing a
barcode until the
next barcode is
recognized.
–
0,5…9,9
0,1