3 608 878 300
Tightening Technology |
Bosch Rexroth AG
37
System 350
| 3 608 878 300/2019-03
Variants
There are the following compact system variants for connecting an ErgoSpin or CC-ErgoSpin hand-held
nutrunner:
•
CS351E-G with TFT display (resolution 640x480) with touch screen
•
CS351E-G IL, additionally with integrated logic (see "Project planning" documentation of the
Rexroth Tightening System 350)
•
CS351E-D with LC display and DVI interface to connect an external DVI monitor
•
CS351E-D IL, additionally with integrated logic (see "Project planning" documentation of the Rexroth
Tightening System 350)
•
CS351E-D NK for networking as slave to a modular system
•
CS351S-G+ with TFT display (resolution 640x480) with touch screen, integrated logic and
integrated computer unit
There are the following compact system variants for connecting an CC-ErgoSpin hand-held nutrunner:
•
CC-CS351E-D with LC display
There are the following compact system variants for connecting a tightening spindle:
•
CS351S-G with TFT display (resolution 640x480) with touch screen
•
CS351S-G IL, additionally with integrated logic (see "Project planning" documentation of the
Rexroth Tightening System 350)
•
CS351S-D with LC display and DVI interface to connect an external DVI monitor
•
CS351S-D IL, additionally with integrated logic (see "Project planning" documentation of the
Rexroth Tightening System 350)
•
CS351S-D NK for networking as slave to a modular system
•
CS351S-G+ with TFT display (resolution 640x480) with touch screen, integrated logic and
integrated computer unit
3.3.2
Modular system
A single communication unit can control up to 40 tightening channels in up to 16 addressable card rack
fields or system boxes. Connecting the servo amplifier to the tightening spindle or ErgoSpin only requires
a single connection cable in each case, which can safely bridge distances of up to 100 meters.
While a tightening system is in a tightening, tightening channels not involved in the tightening must neither
be activated nor deactivated or reset using the Reset pushbutton. Not involved tightening channels must
only be activated, deactivated, or reset outside of tightenings. Otherwise, an acknowledgeable error is
issued.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...