336
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
The following tables explain the data structure.
If the value of a parameter is only defined with numbers, the rest of the characters on the left will be filled
with zeros.
Revision
Is required if different versions are available for the same MID.
Value range: 000 – 999
Example:
3
Revision
1
Value
001
No ack flag
Only for subscription MIDs
Presetting: 0
Reliable mode:
If the No ack flag has not been set (value = 0), the tightening system
will expect acknowledgement of messages.
Unreliable mode:
If the No ack flag has been set (value = 1), the tightening system will
not expect acknowledgement of messages.
1
Reserve
Reserved space for future header expansions.
This space must be filled with eight characters, which will not be
evaluated (e. g. 00000000).
8
Header length
20
Table 6–69:
Message structure in the Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW (Data: General)
Data
Bytes
Example:
Parameter
Value
Value range
Cell ID
01
2
Cell value
0001
0000 – 9999
4
Channel ID
02
2
Channel value
01
00 – 99
2
Tightening system ID
03
2
Tightening system name
Controller 1
25
Value
010001020103Scontroller1
Data length
37
Table 6–70:
Message structure in the Rexroth OP and Rexroth OP-Ford and Rexroth OP-BMW (Data: numbers)
Data
Bytes
Example:
Cell ID value
1
Value
0001
4
Channel ID value
1
Value
01
2
Table 6–68:
Message structure in the Rexroth OP (header)
Header components
Meaning
Bytes
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...