7.7 p/Q PID Control
Fig. 7-8: p/Q PID control
Code
Name
Setting range
Default
Min.
Attri.
F3.12 Proportional gain [0]
0.00...500.00 rpm/bar
8.00
0.01
Run
F3.13 Integral time 1 [0]
0...999 ms
80
1
Run
F3.14 Integral time 2 [0]
0...999 ms
0
1
Run
F3.15 Integral time TI switch
threshold [0]
-150.0...0.0 bar (set to 0, the
switching function is invalid)
0.0
0.1
Run
F3.16 Differential gain [0]
0.000...10.000 (rpm/bar)*s
0.000 0.001
Run
F3.17 Filter time for Kd [0]
0...999 ms
35
1
Run
F3.18 Lower limit for I+D [0]
-5,000...5,000 rpm
0
1
Run
F3.19 System minimum speed [0] -5,000...5,000 rpm
0
1
Run
F3.32 Proportional gain [1]
0.00...500.00 rpm / bar
8.00
0.01
Run
F3.33 Integral time 1 [1]
0...999 ms
80
1
Run
F3.34 Integral time 2 [1]
0...999 ms
0
1
Run
F3.35 Integral time TI switch
threshold [1]
-150.0...0.0 bar (set to 0.0, the
switching function is invalid)
0.0
0.1
Run
F3.36 Differential gain [1]
0.000...10.000 (rpm/bar)*s
0.000 0.001
Run
F3.37 Filter time for Kd [1]
0...999 ms
35
1
Run
F3.38 Lower limit for I+D [1]
-5,000...5,000 rpm
0
1
Run
F3.39 System minimum speed [1] -5,000...5,000 rpm
0
1
Run
Tab. 7-7: Parameter list of p/Q PID control
As default setting the p/Q parameter set 0 (F3.12...F3.19) is selected, switching
to the other parameter set during operation is also possible. For details, please
refer to the following table and figure.
FcP 5020
Bosch Rexroth AG
Block Diagram of Main Functions
DOK-RCON03-FCP5020****-QU04-EN-P
29/83