7.4 Pressure Feedback Input
AI2 input is predefined as the pressure sensor input. User can select a different
type of pressure sensor and scaling factor. In case of Rexroth HM20 pressure
sensor is used the parameter F2.10 use for setting the installed HM20 pressure
sensor.
Fig. 7-6: Pressure feedback input
Code
Name
Setting range
Default
Min.
Attri.
F2.06 Pressure feedback corresponding to 5V,
10V or 20mA
0.1...1,000.0 bar
100.0
0.1
Stop
F2.07 Pressure feedback null offset in V or mA 0.0...5.0 V, mA
4.0
(mA)
0.1
Stop
F3.02 Filter time for pressure feedback
0...999 ms
4
1
Run
Tab. 7-3: Parameter list of pressure sensor feedback scaling
F2.06, F2.07: Scaling for pressure sensor feedback
Fig. 7-7: Pressure sensor feedback scaling
Bosch Rexroth AG
Block Diagram of Main Functions
FcP 5020
24/83
DOK-RCON03-FCP5020****-QU04-EN-P