7.4.5
Assembly Alignment A10VZO
Fig. 7-9:
Suction port
Bottom
Top
Left
Right
A10VZO 010
✔
✔
✖
✖
A10VZO 018
✔
✔
✖
✖
A10VZO 028
✔
✔
✖
✖
A10VZO 045
✔
✔
✔
✔
A10VZO 071
✔
✔
✔
✔
A10VZO 100
✔
✔
✔
✔
A10VZO 140
✔
✔
✔
✔
A10VZO 180
✔
✔
✔
✔
Tab. 7-5:
Allowed assembly variants (suction port)
7.5
Mounting Instruction Internal Gear Pump
7.5.1
Description Assembly Procedure
The assembly procedure is standardized for various motor-pump combina‐
tions. Optional components are indicated in the assembly pictures with (x).
Use mounting screws (number, size, tightening torque) acc. to the tables
about motor-pump units to be mounted.
Assemble the components according to the drawing and observe all assem‐
bly steps. Tolerance of the specified tightening torque (M
A
) ±10%.
For screw connections use screw lock, e.g. Loctite 243® when proceeding
the following working steps 1 to 5 and observe the specified tightening tor‐
ques.
Motor damage due to beats onto the motor
shaft
NOTICE
Do never beat onto the shaft end and do not exceed the allowed axial and
radial forces of the motor.
By heating the hubs (approx. 80 °C), it is easier to draw it on onto the shaft.
Burns by touch of hot hubs!
CAUTION
Wear protective gloves if you assemble heated coupling elements.
DOK-SYTROX-MPES2******-IT01-EN-P
Rexroth Sytronix FcP 50xx/70xx Motor-Pump Unit MPES2
Bosch Rexroth AG
55/143
Mounting