Electric Drives
and Controls
6−13
Bosch Rexroth AG
RhoMotion
1070072367 / 04
SERCOS interface
6.5
Transmission of cyclic drive data to the PCLrho4.0
The data which is transmitted via the SERCOS bus in the cyclic axis te-
legram from the drive to the rho4.0, are copied into the I/O area of the
PCL. The user can have access to drive data that can be chosen and
define himself the configuration of the cyclic axis telegrams within cer-
tain limits.
6.5.1
Definition of the cyclic axis telegrams (AT)
Within the rho4.0
As input buffer for axis telegrams, a maximum of 22 bytes per axis is
defined in the rho4.0. This corresponds to the maximum AT length for
Bosch Rexroth Servodyn-D drives. The number of the identifiers in the
configurable AT for Servodyn-D drives is limited to 5 at the maximum.
The input buffer in the rho4 is assigned as a standard as follows:
S-0-0135
2 Byte
drive status
S-0-0051
4 Byte
position actual value (motor encoder)
S-0-0189
4 Byte
hauling distance
S-0-0144
2 Byte
signal status word
S-0-0084
2 Byte
torque actual value [%]
S-0-0040
4 Byte
velocity actual value
4 Byte
reserve
The drive status is a fixed part of the axis telegram and always present.
The other data is preset by the rho4.0 during the startup via S-0-0016
(configuration list AT) in all drives.
For drives that support only short ATs, the list will be shortened corres-
pondingly.
Example:
Maximum length of
the configurable AT
= 10 bytes
S-0-0016
= (S-0-0051, S-0-0189, S-0-144)
+ 2 bytes drive status
=> Total length = 12 bytes
Содержание Rexroth Rho 4.0
Страница 12: ...XII Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 Contents Notes ...
Страница 22: ...2 2 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 System overview Notes ...
Страница 78: ...4 14 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 PCLrho4 0 Notes ...