REFUspeed RS51
Basic parameterization
7-9
DOK-RD500*-RS51*******-IB02-EN-P
Standard terminal assignment
Parame-
ter No.:
Name
Description / explanation
selectable options
Factory setting
min ... max values
Pass
wor
d
0875
Dig. input, output1
Combined digital input and output
0 =
I
no function (
I
=input)
2 =
I
no alarm ext. (alarm)
3 =
I
no fault ext. (fault)
4 =
I
fault reset
5 =
I
fmin select
6 =
I
direct. rotat. (direction of
rotation reversal)
7 =
I
no volt. disc. (power
disconnected)
8 =
I
no fast stop (fast stop)
9 =
I
RFG park (RFG=ramp-funct.gener.)
10 =
I
RFG-up stop
11 =
I
motp. faster
(motp.=motorized potentiometer)
12 =
I
motp. slower
13 =
I
ALM sensitivity up
14 =
I
ALM sensitivity down
15 =
I
ALM autom. sensitivity adjust.
start / stop
16 =
I
ALM inhibit, sparking
17 =
I
ALM inhibit, load limit
20 =
I
setp. mem. bit4
(weighting 2
4
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
21 =
I
TEST/STANDARD (toggles between
the TEST and STANDARD modes,
simultaneously disables the
changeover from the operator
panel.)
22 =
I
setp. mem. bit0
(weighting 2
0
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
23 =
I
setp. mem. bit1
(weighting 2
1
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
24 =
I
setp. mem. bit2
(weighting 2
2
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
25 =
I
setp. mem. bit3
(weighting 2
3
:
Changes-over the f set, f min, f
max memory and the ramp-function
generator)
26 =
I
parblock bit0
(weighting 2
0
:
Changes-over the specific motor
data
27 =
I
parblock bit1
(weighting 2
1
:
Changes-over the specific motor
data
28 =
I
parblock bit2
(weighting 2
2
:
Changes-over the specific motor
data
O
ALM
sparking signal
0...97
1