CwAck
Clock wise acknowledge: Acknowledges a start
This signal serves to acknowledge the start of the selected tightening program.
CwLockAck
Clock wise lock acknowledge: Acknowledges that start is disabled
This signal serves to acknowledge that a selected tightening program is disabled.
CntNOK
Counter NOK: NOK counter has reached default value
This signal changes to "high" if the set default value of the NOK counter has been reached. The tightening
channel can be optionally blocked when the NOK default value has been reached.
CntOK
Counter OK: OK counter has reached default value
This signal changes to "high" if the set default value of the OK counter has been reached. The tightening
channel can be optionally blocked when the OK default value has been reached.
CyCmp
Cycle Complete: Process end
CyCmp
= "high" signals the end of a tightening operation (sequence and results processing). The
tightening channel is ready for the next tightening.
CyCmp
is set once the current result has been filed to the results database.
CheckTool
Check Tool: Nutrunner test interval reached
This signal turns to "high" when a test interval set in the channel configuration has been reached with the
nutrunner.
EnAck
Enable acknowledge: Acknowledges enabling
This signal serves to acknowledge the release for the start of the nutrunner.
EnScanAck
Enable scanner acknowledge: Acknowledges that the scanner is enabled
This signal serves to acknowledge the release of the scan process:
•
EnScanAck
= 1- Scan process is enabled
•
EnScanAck
= 0- Scan process is disabled
FtpF
Ftp Fault: Results transfer error
Setting: Transfer after completion of the tightening program:
The
FtpF
error signal will be set to "high" if a disruption occurs during the transfer to the FTP server. This
signal will be automatically set to "low" after the next successful data transfer.
Setting: Transfer before completion of the tightening program:
If transfer via Ethernet is not possible, the tightening program or tightening process is stopped
immediately. The
FtpF
error signal is "high" (FTP error) and the corresponding entry is made in the Error
list.
GradAvrH
Gradient average too high: Gradient average value too high
Results description after a completed tightening sequence. The gradient average value exceeds the
defined tolerance window.
GradAvrL
Gradient average too low: Gradient average value too low
Results description after a completed tightening sequence. The gradient average value is below the
defined tolerance window.
The signal is only updated outside of the tightening operation.
Details on data output and its chronological order can be found in the individual chapters of
.
Содержание Rexroth Nexo
Страница 4: ...4 279 Bosch Rexroth AG Tightening Technology ...
Страница 256: ...256 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 ...
Страница 262: ...262 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 263: ...3 608 870 A47 Tightening Technology Bosch Rexroth AG 263 279 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 264: ...264 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 274: ...274 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...
Страница 276: ...276 279 Bosch Rexroth AG Tightening Technology 3 608 870 A47 Nexo cordless Wi Fi nutrunner 3 608 870 A47 2019 10 ...