8
Commissioning and
operation
8.1
Safety
WARNING
High electric voltage! Danger to life, risk of injury
by electric shock.
−
Life parts are dangerous.
Do not open any covers or flange sockets
during operation.
Never connect or disconnect plug connec-
tors under load!
WARNING
Risk of injury due to rotating motor shaft!
−
Do not remove any covers, machine parts or
protection devices during operation.
Do not enter the range of movement of the
machine. Avoid unintended access for per-
sons, due to
−
Safety fences, safety screens or pro-
tective covers.
−
Optical sensors
CAUTION
Thermal danger due to hot surfaces with temper-
atures over 60 °C during operation
−
Do not touch hot motor surfaces.
Install protection against contact, if neces-
sary.
Make sure that no temperature-sensitive
components (cables, electronic compo-
nents, ...) touch hot surfaces.
All persons working with motors (responsible
persons, mechanics and planners) must have
knowledge, skills and competence according to
EN 60079-14:2014.
8.2
Commissioning
MS2N Motors can only be commissioned with
other components (drive controller, control unit).
Prior to commissioning
Prior to commissioning, ensure that the following
requirements are met.
•
Storage time of the motor. Depending on
the storage time, take measures to ensure
safe operation. Run in bearings, resurface
the holding brake, ... See .
•
Ensure that all device connector are correctly
connected and protected against coming
loose.
•
Ensure that a holding brake voltage of
24
V
±10% is applied to the motor. If neces-
sary, adjust the voltage.
•
Check the proper function of the holding
brake.
•
Ensure that the motor and all participating
components of the drive are undamaged.
•
Ensure that keys are protected against ejec-
tion.
Commissioning
For start up procedure refer to the project plan-
ning manual and the respective documentation
about drive controller or firmware description.
Observe the general safety notes.
8.3
Ambient conditions
during operation
Climatic conditions are defined in classes
according to EN
IEC
60721. The classes are
differentiated in the areas storage, transport and
operation. They are based on long-term expe-
riences and take all influencing variables into
account, e.g., air temperature and air humidity.
Commis
sioning and oper
ation