6.2.13 Connect forced ventilation 3 pole + PE (115 / 230 V)
The supply voltage of forved ventilation is characterized by "A" (230 V) or "B"
(115 V).
Use a connection cable 3 x 0.75 mm
2
for connection.
Fig. 6-6: Plug connector 3pole + PE (115 / 230 V)
Assignment
Connection
1
L1 230 V
Screwed connection 0.5 ... 1.5 mm
2
2
N
3
L1 115 V
PE
Tab. 6-29: Pin assignment plug connector 3-pole + PE (115 / 230 V)
The plug insert can be mounted in any position into the connector
housing. Therewith, the cable output direction can be done in steps
of 90 degrees.
Mounting instruction fan connector
1. Dismantle the fan connector
- Removing the housing screw (4)
- Dismount plug insert
- Loosen the cable gland and remove single parts, screwed connection (1),
washer (2) and sealing (3)
74/101