29 / 74
MKE Synchronous Servomotors
Features and functions
Bosch Rexroth AG
R911402016, Edition 02
Fig. 2: Temperature-resistance diagram
according to IEC60034-11:2004, DIN
44081
(single), DIN
44082 (drilling).
Temperature range Resistance
Measuring voltage
[V
DC
]
-20
°C to T
REF
-20K 20
Ω
to 250
Ω
≤
2.5
V
Temperature range 90 °C - 160 °C
T
REF
-5K
≤
550
Ω
≤
2.5
V
T
REF
+5K
≤
1,330
Ω
≤
2.5
V
T
REF
+15K
≤
4,000
Ω
≤
7.5
V pulsed
The resistance rises sharply in the range of the
nominal response temperature. This change can
be made via an electronical evaluation within the
drive controller or with an additional evalutation
device. Depending on the converter used, func-
tion-tested triggering devices with the II 2 G
or II 2 D designation may be required to eval-
uate the temperature sensors. For supplemen-
tary information on temperature monitoring, see
EN
60079-14:2014.
Safe disconnection of the load circuit must be
ensured.
The threshold values for motor temperature mon-
itoring are contained in the encoder data memory
and are read in and monitored automatically
during the operation with compatible Rexroth
controllers. Threshold values for MKE motors are:
•
Motor-warning temperature (125
°C)
•
Motor-disconnection temperature (130
°C)
The temperature signal is transmitted via the
motor interface -X2 (T1, T2).
Monitoring for a maximum value of the resistance
ensures that any cable breakage that may occur is
detected as a fault.
6.2.4
Cooling mode
Self-cooling (IC410)
In case of self-cooling motors, the heat dissipa-
tion is realized via natural convection and radia-
tion to the ambient air as well as by heat conduc-
tion to the machine construction.
The specified nominal data is reached at ambient
temperatures of 0 ... 40 °C. Unhindered vertical
convection has to be ensured by a sufficient dis-
tance of 100 mm to adjacent components. The
allowed limit temperatures must be kept in the
case of deviating minimum distances.
Pollution of the surface of the motor reduces heat
dissipation and can result in thermal overload.
The availability of the system can be increased by
regular checks and cleaning of the motors. Please
ensure access to the motors for maintenance pur-
poses.
Содержание Rexroth MKE
Страница 1: ...MKE Synchronous Servomotors acc to ATEX Directive 2014 34 EU Operating Manual R911402016 Edition 02 ...
Страница 71: ...71 74 MKE Synchronous Servomotors Bosch Rexroth AG R911402016 Edition 02 W Warning temperature 29 Winding 31 ...
Страница 72: ...72 74 MKE Synchronous Servomotors Bosch Rexroth AG R911402016 Edition 02 ...
Страница 73: ...73 74 MKE Synchronous Servomotors Bosch Rexroth AG R911402016 Edition 02 ...