13.2
Commissioning
The following points have to be noted when commissioning MBT motors in
particular:
Parameters
MBT motors are kit motors whose single components are - completed by an
encoder system - directly installed into the machine by the manufacturer. As
a result, kit motors do not feature any data memory to provide motor parame‐
ters, standard controller settings, etc. All parameters must be manually en‐
tered or loaded to the drive during commissioning. The commissioning pro‐
gram from Rexroth provides all Rexroth motor parameters.
Encoder polarity
The encoder polarity has to be set before the commutation is adjusted, taking
the direction of rotation of the rotor into account.
Also see
chapter 13.6 "Determining the polarity of the encoder system" on
fig. 13-2 "Direction of rotation of the rotor, as viewed from the
cable output side at the stator (MST)" on page 390
Commutation adjustment
At MBT motors, the position of the rotor to the stator has to be determined
immediately after power-up or a malfunction. This is referred to as pole posi‐
tion detection or commutation adjustment. This means that the commutation
adjustment is the establishment of a position reference to the electrical or
magnetic model of the motor. The commutation adjustment method depends
on the encoder type used.
Applicable documents
In addition to the motor documentation contained herein, commissioning of
the motors requires the following documents:
●
Rexroth IndraDrive Firmware for Drive Controllers, Functional Descrip‐
tion, DOK-INDRV*-MP*-02VRS**-FK□□-□□-P
●
Rexroth IndraDrive Drive Controllers, Parameter Description, DOK-
INDRV*-GEN-**VRS**-PA□□-□□-P
●
Rexroth IndraDrive Troubleshooting Guide, DOK-INDRV*-GEN-
**VRS**-WA□□-□□-P
13.3
General requirements
13.3.1
General information
The following requirements have to be met to ensure successful commission‐
ing:
●
Compliance with safety-related guidelines and instructions
●
Check of electrical and mechanical components for reliable functioning
●
Availability and provision of required tools
●
Adherence to the commissioning procedure described below
13.3.2
Checking all electrical and mechanical components
Check all electrical and mechanical components prior to commissioning and
pay particular attention to the following issues:
384/409
Commissioning, operation and maintenance
MBT High Synchronous Torque Motors
Bosch Rexroth AG R911298798_Edition 08
Содержание rexroth MBT
Страница 1: ...MBT High Synchronous Torque Motors Project Planning Manual R911298798 Edition 08 ...
Страница 18: ...6 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 32: ...20 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 240: ...228 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 298: ...286 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 416: ...404 409 MBT High Synchronous Torque Motors Bosch Rexroth AG R911298798_Edition 08 ...
Страница 421: ...Notes MBT High Synchronous Torque Motors 409 409 ...