The terminal box can only be used for double cabling for
power connection.
●
Fuses F1 (NH...) protecting the wires against overload in
case of a cable break must be dimensioned according to the
current carrying capacity of the particular line cross-section.
●
The fuses should be installed in the control cabinet such that
they are as close as possible to the power output of the con‐
troller.
●
The shield of the motor power cable must be connected to
the control cabinet on the motor side of the fuses such that it
is conducting over a large area.
●
No special power cables are available to establish the dou‐
ble cabling. To install the fuses, standard Rexroth power ca‐
bles have to be opened and cut to the appropriate length on
site.
6.2.4
Connect motor fan (only for MAD motors)
The motor fan is connected to the supply network via a cable and a motor
protective switch and is operated independently of the controller.
1
2
3
M
3
4
①
RLS0782
RLS0782
②
③
④
0,75 … 1,5 mm²
0,75 … 1,5 mm²
0,75 … 1,5 mm²
L1 L2 L3 PE
①
Power connection cable diameter Ø 7 ... 10 mm
②
Protective switch
③
Plug connector
④
Fan
Fig. 6-9:
Fan connection
●
To connect the motor fan, the fan connector must be opened
and closed.
●
The connector for connecting the motor fan is included in the
scope of delivery and is located on the motor fan.
●
Electric connection may only be established by specialized
staff. Observe the safety instructions.
●
The tightness of the connector housing may not be reduced.
●
Motor protective switch and electric fusing are selected by
the machine manufacturer. Please observe the regulations
in the country of installation.
MAD / MAF Asynchronous Housing Motors
29/57
Assembly
R911336186_Edition 02 Bosch Rexroth AG
Содержание Rexroth MAD100
Страница 1: ...MAD MAF Asynchronous Housing Motors Operating Instructions R911336186 Edition 02 ...
Страница 20: ...6 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 22: ...8 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 48: ...34 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 54: ...40 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 60: ...46 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 62: ...48 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 66: ...52 57 MAD MAF Asynchronous Housing Motors Bosch Rexroth AG R911336186_Edition 02 ...
Страница 69: ...Notes MAD MAF Asynchronous Housing Motors 55 57 ...
Страница 70: ...Notes 56 57 MAD MAF Asynchronous Housing Motors ...
Страница 71: ...Notes MAD MAF Asynchronous Housing Motors 57 57 ...