Fig. 6-8:
Switching communication with the MTX micro to online
6.3.6
Errors in communication with the MTX micro
If communication with the MTX micro is disturbed upon switching to online
mode, the following dialog is displayed:
Fig. 6-9:
Communication error
Possible remedies:
1. Check whether the Ethernet cable is properly connected
2. Use an Ethernet crossover cable if your PC does not support the "Auto‐
sensing" function
3. Recheck the settings of the IP addresses of the PC and the MTX micro
4. Switch the PC and the MTX micro off and on again
6.4
Downloading the CNC configuration data
After communication has been successfully established, the CNC parameters
of the basic project must be downloaded to the MTX micro. To do this, extract
these parameters from an archive ("TAR File") which is an integral part of the
basic project. Proceed as shown in the description below.
From version 12
1.
Select the "IndraMotion_MTX_micro" node. Right-click on this node and
select "Restore…" from the context menu
2.
Select the partial archives to be loaded