Fig. 5-27:
Assigning the digital inputs and outputs of the MTX micro
●
Inputs X83.1, X83.2 as well as X86.1 to X86.3 and output
X81.1 are reserved for the system PLC program.
●
The X84.1 to X84.8 inputs and the X82.1 to X82.8 outputs
can be assigned to the "Digital inputs/outputs (DigIO)" (PLC/
DigIO/).
●
Inputs X86.1 (%IX10.0) to X86.4 (%IX10.3) are what are
called "fast inputs". These inputs can be directly processed
in position loop clock.
●
Inputs X86.2 and X86.3 should be kept free for the use of
touch probes, even if the machine is not equipped with touch
probes.
Control cabinet design
The following instructions on setting up the control cabinet should be followed
to ensure smooth operation of the MTX micro. The arrangement of the com‐
ponents was based on the discharge of the developing power losses, on the
prevention of faults due to electromagnetic influence, and on the position of
the connection points.
DOK-MTXMIC-EASY*******-CO06-EN-P
Bosch Rexroth AG
57/177
IndraMotion MTX micro Easy Setup for Standard Turning and Milling Machines
Selecting and connecting the hardware