is displayed only with its error number. More information can be obtained in the
operating area "Diagnostics" of the standard user interface of the control.
The "Output" window displays all messages of the control with text and symbol:
●
Error
●
Warnings
●
Notes (PRN#(0,...), MSG , GMSG )
In case of errors and warnings, the color of the symbols shows whether the
message:
●
is pending: Background color of the symbol: Red
●
is deleted or has already been read: Background color of the symbol: blue
Deleting messages in the "Output"
window
Activating the "Output" window. Delete all messages with <F4 Delete output>.
Active Program after Abort
If an active program is terminated due to an error, the NC-Analyzer can be used
to perform a static inventory of the variables used for all active programs. With
the stack, local variable states in subroutines can be checked as they were valid
at the time of the subroutine call.
To perform this inventory, the interrupted program still needs to be selected in
the NC.
Breakpoints cannot be set in this state because the Analyzer mode is not active
in the NC-Analyzer. If you try to switch to Analyzer mode, an error message is
displayed:
Starting the NC-Analyzer
●
Starting the NC Analyzer
●
Selecting the channel with the incorrect program
–
The location at which the NC program was stopped due to an error
is shown in the "Program" window of the NC-Analyzer.
–
The call structure (in case of a possible subroutine nesting in the NC
program) is shown in the "Stack" window
–
Subroutines can be selected in the "Stack" window and displayed via
<F5 Go to start> in the "Program" window to analyze their program
variables
The error can often be found only with this information.
At least, the incorrect program section is known which can be analyzed in
the Analyzer mode.
Testing the program
Before further machining, the program should once again be tested on error
absence in the program. The NC-Analyzer can be a very helpful tool here as
well, since the values of the variables used can be called at any time during the
program execution.
Messages of the NC-Analyzer
System and user messages of the NC-Analyzer are shown in popup windows
with error text classification.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Bosch Rexroth AG
241/301
Extended Functionality
Содержание Rexroth IndraMotion MTX 11 VRS
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 14: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 12 301 ...
Страница 26: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 24 301 ...
Страница 36: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 34 301 ...
Страница 76: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 74 301 ...
Страница 114: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 112 301 ...
Страница 160: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 158 301 ...
Страница 290: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 288 301 ...
Страница 294: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 292 301 ...
Страница 303: ...Notes DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation Bosch Rexroth AG 301 301 ...