Rexroth IndraMotion MLD
Preparation and Assembly
4-5
DOK-IM*MLD-F*STEP**V**-KB01-EN-P
4.4
Step 4: Establish Communication Between Drive and
Commissioning PC
Establishing the Serial Connection to IndraDrive
•
Establishing connection between PC and drive.
The commissioning PC is connected to the drive via the serial
interface by means of the
IKS0199 / 00x.0
interface cable at X2.
•
Start
IndraWorks
•
Select "Connect online with IndraDrive (serial)"
•
Select serial interface
•
Select device from "List of all found devices" and complete procedure
with "Finish"
DB000215v01_en.tif
Fig. 4-3:
Establishing connection via serial interface of PC to drive
Establishing the Ethernet Connection to IndraDrive
Requirements
The following components and requirements are necessary to establish
Ethernet communication with the IndraDrive controller:
•
CSH01
.2
control section with Ethernet engineering interface
•
firmware MPx04V12 or higher
•
standard Ethernet cable
•
unassigned Ethernet connection at PC