Availability for axis
Name
Axis1 (local
axis)
"Axis2" to "Axis10"
(remote axes)
VmAxisInt
VmAxisExt
RmAxis
LinkAxis1
MX_Command
X
X
--
--
--
--
MX_SetControl
X
--
--
--
--
--
MX_SetDeviceMode
X
--
--
--
--
--
MX_SynchronControl
X
--
--
--
--
--
MX_fGetDriveWarning
X
--
--
--
--
--
MX_fSetDriveError
X
--
--
--
--
--
MX_fSetDriveWarning
X
--
--
--
--
--
Tab. 4-4:
General function blocks/functions
Assigning the logical MLD-M axis number to sercos address of CCD slaves
Axis numbers 2 to 10 (AxisNo=AXIS_2 to AXIS_10) of an MLD-M system are
real axes in the CCD slaves. Axis number 1 represents the local axis in the
CCD master. The AXIS_REF variables and their "AxisNo" are used for pro‐
gramming in the PLC user program. This gives a maximum of 10 real axes
with the logical numbers 1 to 10 in an MLD-M system.
The sercos addresses are assigned to logical axis numbers 1 to 10 in MLD-M
through the sercos address setting for the CCD master and for the CCD
slaves via the order of sercos addresses of the remote drives in parameter
"P-0-1601, CCD: Addresses of projected drives" or in the "Cross Communi‐
cation Drive: Settings" dialog box in IndraWorks.
Fig. 4-13:
"Cross Communication Drive: Settings" dialog box
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
56/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Basic functions of Rexroth IndraMotion MLD
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01