Fig. 9-8:
Subsequently Installing a Device Version
The "Open File" Windows dialog is opened.
3.
Select the package to be installed. (It is only allowed to select files with
the ".iwpackage" extension!)
The installation can take some time.
After the installation, the new device version is available in the drop
down list for selection.
4.
Select the new device version via the drop down list.
5.
Click the Change Device Version button.
6.
After the device version has been changed, the project should be
cleaned:
In the main menu, execute Build ▶ Clean all.
7.
The cleaned project must be rebuilt:
In the main menu, execute Build ▶ Rebuild all.
The cleaned and rebuilt project will be loaded to the control unit
with the next "Login".
9.4.4
Replacing the Controller
Overview
A controller of the IndraDrive range consists of the components power sec‐
tion, control section and programming module / control panel (incl. firmware).
The control section can be configured with additional components (e.g., op‐
tional safety technology module). The control section and power section are
firmly connected; only Rexroth service engineers or especially trained users
are allowed to replace individual components. The paragraphs below de‐
scribe how to replace the complete controller.
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
250/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Diagnostic and service functions
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01