however, is not deleted as it is the case with the "Clean all" command.
Please note that you can exclude objects from compilation.
●
Reset
–
"Reset" [corresponds to "Reset (hot)"]: Reset program; retain varia‐
bles retain their values
–
"Reset (cold)": Reset program; retain variables are initialized
–
"Reset (original)": Program and boot project are deleted
Stopping IndraMotion MLD (emergency mechanism)
Motivation
Since a boot project is automatically loaded and, depending on the configura‐
tion, started during the run-up of the drive, a mechanism has been implemen‐
ted which can prevent the start of PLC programs.
Usage information/sequence
Proceed as follows to prevent PLC programs from starting while the drive is
starting up:
●
In the boot-up phase, before Boot 2.9 is displayed on the control panel,
the "ESC" and "ENTER" keys have to be simultaneously pressed and
held on the control panel.
●
The automatic start of a PLC boot project is prevented and the display
reads "PLC?".
●
By pressing the arrow keys (arrow down or arrow up) the display
switches between "Run PLC" and "Stop PLC".
If "Stop PLC" is confirmed with "ENTER", no project is loaded; if "Run
PLC" is confirmed with "ENTER", a possibly stored project is started or
loaded.
9.4.2
Changing firmware
Overview and introduction
There is a difference between a firmware release update and a firmware ver‐
sion upgrade when changing the firmware
Note the following when changing the firmware:
●
For firmware release updates, the device version is updated, if necessa‐
ry; it contains the libraries of old releases.
●
Each new firmware does not contain new or modified libraries. If there
are not any new or modified libraries, no new IndraWorks package is
provided.
●
Any new firmware version or a different characteristic includes a new
IndraWorks package (examples: MPB17→MPC17, MPB17→MPB18)
Firmware release update
General
With a firmware release update, a firmware of the same version is brought to
a new release status (e.g., MPB17V08 to MPB17V10).
The general procedure for carrying out a firmware release update is ex‐
plained in the Functional Description of the firmware in the Section "Changing
firmware".
The paragraphs below only describe the MLD-specific behavior
and procedure.
Use and content of firmware re‐
lease notes
The "Firmware release notes" provide information on firmware versions and
their compatibility.
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
246/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Diagnostic and service functions
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01