Diagnostic and status information
The following parameters are used for running diagnostics on PLC projects
(technology function):
●
P-0-1360, PLC program identifier
●
P-0-1361, PLC program name
●
P-0-1351, PLC status word
7.3.3
Free programming of Rexroth IndraMotion MLD
Connection to the drive
General information
Communication between the PLC programming user interface IndraLogic and
the drive is made available via the IndraWorks MLD commissioning software.
The connection is set in IndraWorks MLD. With "Scan for devices", for exam‐
ple, the connection can be automatically set.
IndraLogic is started from IndraWorks MLD by double-clicking the "Logic"
branch in Project Explorer. IndraLogic automatically applies the communica‐
tion setting from IndraWorks MLD; the IndraLogic dialog for setting the com‐
munication parameters is not required.
You should only start IndraLogic from IndraWorks MLD; operation
of IndraLogic without the embedding in IndraWorks MLD is not
supported.
Bosch Rexroth AG
DOK-INDRV*-MLD3-**VRS*-AP02-EN-P
170/267
Rexroth IndraDrive Rexroth IndraMotion MLD (2G) as of MPx-18
Notes on commissioning and application