Rexroth IndraDrive
Command Diagnostic Messages
9-117
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C3502 Motor encoder not available
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
P-0-0340, C3500 Command
Determine encoder correction values
an error was detected.
Cause
Remedy
Motor encoder does not supply any signal or is not
recognized by controller
Check whether signals of motor encoder are reaching
controller. If necessary, replace motor encoder or motor
encoder cable
Motor encoder not available, not connected or not
registered ("open-loop" operation)
Connect motor encoder and register it in
P-0-0074,
Encoder type 1 (motor encoder)
C3502 - Attributes
Display:
C3502
Mess. no.:
C3502 (hex)
C3503 Optional encoder not available
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the execution of the command
P-0-0340, C3500 Command
Determine encoder correction values
an error was detected.
Cause
Remedy
Optional encoder does not supply any signal or is
not recognized by controller
Check whether signals of optional encoder are reaching
controller. If necessary, replace encoder or encoder
cable
Optional encoder not available, not connected or not
registered
Connect optional encoder and register it in
P-0-0075,
Encoder type 2 (optional encoder)
C3503 - Attributes
Display:
C3503
Mess. no.:
C3503 (hex)