9-46
Command Diagnostic Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
C0161 Incorr. prarmeterization of measuring enc. (hardware)
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
During the transition check from communication phase
2 to
communication phase
3 (C0100) an error with regard to the
parameterization of the hardware of the measuring encoder was detected.
Cause
Remedy
Parameterization of
P-0-0076, Encoder type 3
(measuring encoder)
does not match interface card
(e.g. EN1 with EnDat encoder)
Correct parameterization of
P-0-0076, Encoder type 3
(measuring encoder)
P-0-0079, Assignment measuring encoder
->optional slot
incorrectly parameterized
Correct parameterization of
P-0-0079, Assignment
measuring encoder ->optional slot
or change control
section configuration (replacement of control section or
drive controller)
In the case of double-axis device (CDB control
section)
P-0-0076, Encoder type 3 (measuring
encoder)
was parameterized unequal "0" for both
axes
Only one measuring encoder can be connected per
double-axis device (CDB control section).
P-0-0076,
Encoder type 3 (measuring encoder)
may only be
unequal "0" for one axis
Note:
Only Rexroth service engineers or especially trained users are
allowed to replace the control section. The replacement of the
entire drive controller is described in the Project Planning
Manual for the power section.
See also Functional Description "Measuring Systems"
C0161 - Attributes
Display:
C0161
Mess. no.:
C0161 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01