Rexroth IndraDrive
Error Messages
7-113
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F2104 Commutation offset invalid
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
The commutation offset value stored in the motor encoder memory was
detected to be invalid.
Note:
The motor mustn
’
t be operated without valid commutation
offset!
Cause
Remedy
Failure occurs sporadically (firmware error)
Clear error. Then execute command
P-0-0524, C1200
Commutation offset setting command
; if error occurs
again contact our service department in order to get a
firmware update
Encoder memory or encoder electronics is defective
Clear error. Replace encoder or motor. Then execute
command
P-0-0524, C1200 Commutation offset
setting command
.
See also Functional Description "Commutation Setting"
F2104 - Attributes
Display:
F2104
Mess. no.:
F2104 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01