7-92
Error Messages
Rexroth IndraDrive
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
F2039 Maximum acceleration exceeded
Supported by Firmware Variant:
FWA-INDRV*-
MPH02
VRS-MS
FWA-INDRV*-
MPB02
VRS-MS
FWA-INDRV*-
MPD02
VRS-MS
In cyclic position control the allowed acceleration limit value was
exceeded.
Note:
The acceleration monitor can be switched off by means of
P-0-0556, Control word of axis controller
.
Cause
Remedy
Value in
S-0-0138, Bipolar acceleration limit value
too low
Check and, if necessary, correct parameterization of
S-0-0138, Bipolar acceleration limit value
Incorrect command values set by control unit
(position command values)
Contact control unit manufacturer or programmer
Preset acceleration value was greater than value
parameterized in
S-0-0138, Bipolar acceleration
limit value
Reduce acceleration value used
-
S-0-0042, Homing acceleration
-
S-0-0260, Positioning acceleration
-
P-0-0057, Return acceleration
F2039 - Attributes
Display:
F2039
Mess. no.:
F2039 (hex)
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01