MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-91
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Input:
S-0-0328,7,w,> (CR)
?
1
(CR)
bit1
?
2 (CR)
bit2
etc.
?
<(CR)
E01:>
Errors Messages in the Case of ASCII Communication
The following error messages specifically occur in the case of
communication with ASCII protocol:
Error code
Description
0x9001
fatal error (characters cannot be identified)
0x9002
parameter type error
0x9003
invalid data block number
0x9004
input cannot be identified
0x9005
data element number not defined
0x9006
error in the write-read identifier (r/w)
0x9007
invalid character in the data
Fig. 10-51: Error messages in the case of ASCII communication
Communication with SIS Protocol
Telegram Structure, Telegram Frame
An SIS telegram is basically divided into 3 blocks:
•
telegram
header
•
useful data header
•
useful
data
telegram header
useful data header
useful data
Fig. 10-52: Structure of an SIS telegram
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪