The drive firmware allows activating and deactivating the write protection
for parameter values by means of three hierarchically different
passwords:
•
Customer password
The parameter values of a parameter group combined by the
customer can be protected.
•
Control password
Parameters protected by a customer password can be written;
"administration parameters" remain write-protected.
•
Master password
All parameters that can be written, including "administration
parameters" and parameters protected by a customer password, can
be changed.
Commands
Commands are used to activate and control complex functions or
monitoring features in the drive. The higher-level master can start,
interrupt or clear commands.
Each command is assigned to a parameter by means of which the
execution of the command can be controlled. During the execution of the
command the display of the control panel reads "Cx", "C" representing the
diagnostic command message and "x" representing the number of the
command.
Note:
Each command that was started must be actively cleared
again.
All commands available in the drive are stored in the
S-0-0025, IDN-list
of all procedure commands
parameter.
There are 3 different kinds of commands:
•
Drive control commands
•
can cause automatic drive motion,
•
can be started only when drive enable has been set,
•
deactivate the active operating mode during its execution.
•
Monitoring commands
•
activate or deactivate monitors or functions in the drive.
•
Administration commands
•
carry out administration tasks,
•
cannot be interrupted.
See also "Command Processing" in chapter "Master Communication"