![Bosch Rexroth IndraDrive Mi Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/bosch/rexroth-indradrive-mi/rexroth-indradrive-mi_project-planning-manual_40585095.webp)
Power dissipation, mounting position, cooling, distances
Cooling and power dissipation data
Description
Symbol
Unit
KMV03.1R-B0007-P-D7-ET-NNNN
Ambient temperature range for
operation with nominal data
T
a_work
°C
0…40
Allowed mounting position
G1, G2, G3, G4
Cooling type
Thermal interface
Power dissipation at continuous
current and continuous DC bus
power respectively
1)
P
Diss_cont
W
500.00
Power consumption control volt‐
age input at U
N3
2)
P
N3
W
18
Temperature increase with mini‐
mum distances d
bot
; d
top
; P
BD
ΔT
K
-
Last modification: 2016-02-11
1)
Plus dissipation of braking resistor and control section
2)
See information on "Rated power consumption control voltage
input at U
N3
"
Tab. 5-11:
KMV - Cooling and power dissipation data
Rated power consumption control voltage input at U
N3
Plus power consumption of externally connected inputs/outputs,
plus safety option
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
93/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01