![Bosch Rexroth IndraDrive Mi Скачать руководство пользователя страница 92](http://html.mh-extra.com/html/bosch/rexroth-indradrive-mi/rexroth-indradrive-mi_project-planning-manual_40585092.webp)
5.5
KMV03 supply unit
5.5.1
Ambient and operating conditions
Ambient and operating conditions - UL ratings
Description
Symbol
Unit
KMV03.1R-B0007-P-D7-ET-NNNN
Short circuit current rating
SCCR
A rms
42000
Rated input voltage, power
1)
U
LN_nenn
V
3 x AC 380…500
Rated input current
I
LN
A
12
Output voltage
V
out
V
DC 750
Output power
P
out
kW
7.5
Last modification: 2016-03-08
1)
For use on a solidly grounded wye source only.
Tab. 5-9:
KMV - Ambient and operating conditions - UL ratings