4
General data and specifications
4.1
Acceptance tests and approvals
Declaration of conformity
Declarations of conformity confirm that the components comply with the valid
EN standards and EC directives. If required, our sales representative can
provide you with the declarations of conformity for components.
Drive controllers,
Supply units
Motors
CE conformity regarding
Low-Voltage Directive
EN 61800-5-1:2007
EN 60034-1:2010+Cor.:2010
EN 60034-5:2001+A1:2007
CE conformity regarding
EMC product standard
EN 61800-3:2004 + A1:2012
Tab. 4-1:
CE - applied standards
C-UL-US listing
The components are listed by UL (Underwriters Laboratories Inc.®).
Proof of certification can be found online:
Under "UL File Number" enter the file number or under "Company Name" en‐
ter the company name "Bosch Rexroth AG".
UL ratings
When using the component in the scope of CSA / UL, observe the
UL ratings for each component.
Only the following components have been approved in the scope
of CSA / UL for supplying KCU, KSM, KMS components:
●
HMV01.1E
●
HMV01.1R
●
HMV02.1R
●
HCS01.1E
●
HCS02.1E
●
HCS03.1E
●
KMV03.1R
Make sure that the indicated SCCR short-circuit rating is not ex‐
ceeded, e.g., by using appropriate fuses in the mains connection
of the supply unit.
Wiring material UL
In the scope of CSA / UL, use copper 60/75 °C only; class 1 or
equivalent only.
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
47/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
General data and specifications
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01