![Bosch Rexroth IndraDrive Mi Скачать руководство пользователя страница 194](http://html.mh-extra.com/html/bosch/rexroth-indradrive-mi/rexroth-indradrive-mi_project-planning-manual_40585194.webp)
6.7.7
XG34, mains contactor control and feedback contacts
View
Connection Function
1
Mains contactor control (N/C contact)
2
3
Mains contactor feedback (N/O contact)
4
Tab. 6-83:
Pin assignment
Mechanical data
Spring terminal (connector)
Unit
max.
Connection cable
Stranded wire
mm
2
1.5
AWG
16
Stripped length
mm
10
Tab. 6-84:
Mechanical data
Electrical data
Screw terminal (connector)
Unit
Value
Nominal current
A
8
Rated voltage
V
160
Tab. 6-85:
Electrical data
Cables
Description
Value
Order type
Maximum allowed length
1 m
Tab. 6-86:
Cables
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
192/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points