6.4.9
X156, Motor Connection
View
Connection
Signal name
Function
U1, V1, W1
-
Power output
PE
-
Equipment grounding conductor
5
Temperature measurement input
6
MotTemp-
7
Br+ / +24V
Output for controlling the motor holding
brake of the "applied without current"
type
8
Br- / 0V
9
GND_shld
Shield
9-pin, female connector
Unit
Min.
Max.
Output for controlling the motor holding brake (X156.7/8)
Output current (A)
A
0,15
1)
1
Continuous power overvoltage protection (B)
W
n.s.
1,5
Energy absorption (B)
Ws
n.s.
3
Cable
RKL4305
Allowed length
m
n.s.
7,5
1)
With deactivated brake current monitoring: 0 A
Tab. 6-33:
X156, Motor
6.4.10
Second connection point of equipment grounding conductor
See
chapter 6.3.9 "Second connection point of equipment grounding con‐
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
165/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points