6.3.6
X118, X119, external communication
The optional connection point X118/X119 is a Multi-Ethernet interface used to
connect components with Ethernet-based communication (sercos III,
PROFINET IO, EtherNet/IP, EtherCAT) in distributed form.
X118, X119
View
Connection
Signal name Function
1
Tx+
Transmit, Differential Output A
2
Rx+
Receive, Differential Input A
3
Tx-
Transmit, Differential Output B
4
Rx-
Receive, Differential Input B
5
Shield
Shield connection
(Only use shielded cables for which the
shield has been connected to ground
over the largest possible surface area via
the housing.)
Female connector M12 (5‑pin, D‑coded)
Ready-made connection cable
●
●
Tab. 6-26:
X118, X119; function, pin assignment, properties
At KMV supply units, the connection points X119 (control unit)
and X103.2 (KMS; alternative: X118 - instead of X103.2 - when
using hybrid cables without communication) have to be used.
Principle of external communica‐
tion
In the case of devices with external communication, the communication sig‐
nals are transmitted in parallel with X103.1 and X103.2 via a circuit board
(see figure: LK_C) to the connection points X118 and X119.
LK_C
Internal circuit board for communication
X_serc
Internal communication interface
Fig. 6-12:
Devices with external communication
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
154/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points