6.2.3
X29.1, X29.2, Multi-Ethernet
The signals at X29.1 are directly looped through to X29.2.
View
Connection
Signal name
Function
1
TD+
Transmit, differential output A
2
TD-
Transmit, differential output B
3
RD+
Receive, differential input A
4
n. c.
-
5
n. c.
-
6
RD-
Receive, differential input B
7
n. c.
-
8
n. c.
-
Housing
Shield connection
Properties
Standard
●
Ethernet
●
Type: RJ-45, 8-pin
Compatibility
100Base-TX according to IEEE 802.3u
Recommended cable type
●
According to CAT5e; type of shield ITP (Industrial Twisted Pair)
●
Ready-made cables which can be ordered:
–
RKB0011
Long cables (100 m at maximum) to connect the drive system to the high‐
er-level control unit or remote communication nodes.
Minimum bending radius:
–
48.75 mm if laid flexibly
–
32.50 mm if laid permanently
Order code for a 30 m long cable: RKB0011/030,0
–
RKB0013
Short cables to connect devices arranged side by side in the control cabi‐
net.
4 lengths available: 0.19 m; 0.25 m; 0.35 m; 0.55 m
Order code for a 0.55 m long cable: RKB0013/00,55
Minimum bending radius: 30.75 mm
Tab. 6-4:
Function, Pin Assignment, Properties
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
130/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03