At a KCU02, exclusively operate KSM02 motor-integrated servo
drives or KMS02/KMS03 near motor servo drives.
For the correct and safe function of the drive, all connection
points must be connected.
At X29.1 or X29.2, X52, X53 and X54, use the hybrid cable RKH
by Rexroth.
6.2.2
X1, Module Bus
Function, Pin Assignment
The module bus is an internal system connection and is used to exchange
data between the devices.
View
Identification
Function
X1 in
Receives the module bus connector
X1 out
Passes the module bus connection to the neigh‐
boring device
Tab. 6-3:
X1, Module Bus
installation Instructions
●
Keep the ribbon cable in the parking position, if the connection to the
neighboring device is not established.
●
If used for the module bus, extension cables must be shielded. Their to‐
tal length may not exceed a maximum of 40 m. The module bus connec‐
tion can be extended by means of accessory RKB0001.
●
When using DC bus capacitor units:
Do not establish this connection at the DC bus capacitor unit, if the DC
bus capacitor unit is the last device in the drive system.
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
129/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Connection points