5.8.2
Hybrid cable without communication, technical data
Data sheet - bulk cable
Description
Symbol
Unit
REH0803
Brief description of cable
(5x2.5mm² + 5x0.34mm²)StC
RoHS
RoHS compliant (according to 2011/65/EC)
Recognized UL and CSA
1)
cURus
AWM Style
AWM21223
Diameter
D
mm
11.4 +/-0.3
Power core cross section
mm
2
2.5
Cable jacket material
2)
PUR
Cable jacket color
RAL2003
Specific cable weight
m
kg/m
0.234
Temperature range for storage
°C
tbd
Ambient temperature at operation
(permanent installation)
°C
-40 … +80
Ambient temperature at operation
(flexible installation)
°C
tbd
Operating temperature at conduc‐
tor (flexible/permanent)
°C
tbd
Leakage capacitance
C
Y_K_typ
Conductor resistance at 20°C (EN
60228; class 6)
R
20
ohm/km
8 (2.5 mm²)
Operational voltage at power
cores
V
850
Operational voltage at control
cores
V
100
Halogens
Halogen-free acc. to VDE 0472, Part 815
Oil resistance
tbd
Flammability
IEC 60332-1-2
Flexible cable tracks
Suitable for application in flexible
cable tracks
Yes
Bending cycles
5
Bending radius with flexible instal‐
lation
mm
8 x D
Bending radius with permanent in‐
stallation
mm
4 x D
Max. acceleration
3)
a
max
m/s²
50m/s² (5m)
Max. travel velocity
4)
v
m/s
5
Last modification: 2016-01-13
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
108/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01