VDP 16.3/40.3/60.3 to one USB connection (XUSB1 up to XUSB6) of the
control cabinet PC by using an USB cable. The USB cable can be ordered as
accessory, see
chapter 11.5.6 "Connecting cables for the USB interface" on
.
Malfunctions of the USB2.0 connection if
USB cables longer than 5 m are used.
NOTICE
The maximum USB cable length of 5 m must not be exceeded for the
USB2.0 cable!
Pin
Function
1
USB power supply (max. 500 mA)
2
Data -
3
Data +
4
USB ground
The general function of non-specification-
compliant USB devices can not be
guaranteed, even if they are functioning e.g.
at the USB interface directly at the control
cabinet PC.
NOTICE
Connect only USB devices that meet the USB specification. However, also
USB devices are commercially available that e.g., do not have the response
times specified in the USB specification.
CDI+: Operating the USB connection at the VDP
The USB2-0 mode is available for all cable lengths.
7.1.5
XSER and XVID interfaces
CDI interface
The CDI interface is assigned to the two RJ45 sockets XSER and XVID. The
connection between the control cabinet PC and the operator display is
established at these sockets via two ready-made cables available as
chapter 11.5.5 "Connecting cables for CDI interface" on page
The CDI interface includes the data interface (XSER) as well as the image
interface (XVID).
Destruction of the CDI interface in the VDP
and in the control cabinet PC if CDI cables
are plugged and removed when voltage is
applied without using a functional earth for
both devices.
NOTICE
The functional earthing (FE) is always to be used.
IndraControl VDP 16.3, VDP 40.3, VDP 60.3 Operator Display
39/57
Interfaces
R911323862_Edition 07 Bosch Rexroth AG
Содержание Rexroth IndraControl VDP 40.3
Страница 6: ...IV IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 12: ...6 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 22: ...16 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 40: ...34 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 48: ...42 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 60: ...54 57 IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Dis play Bosch Rexroth AG R911323862_Edition 07 ...
Страница 63: ...Notes IndraControl VDP 16 3 VDP 40 3 VDP 60 3 Operator Display 57 57 ...