6
-1
Display and Operating Components
6
Display and Operating Components
6.1
Display
The operator terminal is equipped with a STN display.
6.1.1
Setting the Contrast
To define the contrast setting, use the programming software to set up
the system variable
LcdContrast
in any screen.
In the programming software, enter the following values as lower and
upper limits for the representation type.
If you did set-up the system variable, you can set the contrast as fol-
lows. Open the screen where you set up the system variable and:
1. Press the brightness button.
2. Enter a new value for the brightness. To do so, use the keyboard
shown on the screen.
3. Confirm with Enter.
The new contrast setting becomes effective immediately after the Enter
key is pressed. If necessary, repeat the steps two and three until you
are satisfied with the contrast.
Danger of intoxication!
If the display is damaged, avoid touching, swallowing or breathing in the
liquids or gases which may leak out.
Danger of corrosion!
If the display is damaged, avoid touching, swallowing or breathing in the
liquids or gases which may leak out.
To do so, follow the instructions listed in the programming software's
help topic "How do I specify the contrast setting for the operating de-
vice".
System Vari-
able
Lower Limit
Upper Limit
Default Setting
LcdContrast
+ 1
+ 31
+ 15
Fig. 6-1:
Values for the representation type
If you do not configure the system variable
LcdContrast
, the default
setting is used when the device is initialized.