10.2
Fitting Dimensions
Mount the operator display as follows:
Loss of degree of protection IP 65!
The housing in which the operator display is installed, has to fulfil the fol‐
lowing conditions:
● free from impurities
● sufficient mechanical strength and flatness
These criteria influence the required degree of protection IP to a great ex‐
tent.
Further required measures are to be taken depending on the mounting lo‐
cation, e. g. the stabilization of the mounting frame.
1. Create a mounting cut-out with six holes, diameter 4.5 mm, according to the illus‐
trations "Mounting dimensions" on the following pages.
2. Remove the paper strip from the seal on the rear side of the front panel.
3. Insert the operating display from the front into the cut-out. The M4 mounting bolts
have to be inserted into the drilled holes.
4. Fasten the operating display by screwing the nuts at the rear side of the mounting
bolts.
Mechanic damage due to incorrect mounting torque.
NOTICE
Tighten the screws and nuts with the corresponding torque according to the following
table.
Threads
Mounting torques
M4
1.4 Nm
Fig.10-1: Mounting torques
DOK-SUPPL*-VAK*X1.2***-IT01-EN-P
Rexroth IndraControl VAK 11.2, 41.2 Membrane Keyboard
Bosch Rexroth AG
Mounting
11/21