RE 63124-B, Edition: 08.2021, Bosch Rexroth AG
Assembly |
Press modules Type IH04 25/56
7.3 Assembling the press module
WARNING
Pressurized press components due to stored pressure energy (e.g. press slide
working under gravity, pressurized lines over 50 bar according to EN 289,
par. 4.3.1.2) even after switching off the energy supply! Ejection of valves and
leakage of pressurized hydraulic fluid!
Danger to life! Risk of injury! Explosion hazard, risk of fire, health hazard,
environmental pollution! Damage to property!
▶ Before working on the press module, check that the EMERGENCY stop on
the press is effective and that the power circuit is disconnected from the
press module. Gravity-loaded axes must be in the lowest position, if possible,
or the load must be held securely by a mechanical restraint device.
▶ Secure the press against restarting by selecting the OFF operating mode and
then removing the key.
▶ Never try to stop or seal the leakage or the hydraulic fluid jet using a cloth.
▶ Do not disconnect pipe/hose connections, connections or components as long
as the press module is pressurized.
▶ Check the pressure at the provided measuring ports only after the hydraulic
fluid jet has subsided.
CAUTION
Insufficient assembly space!
Risk of injury! Danger of crushing! Danger of trapping your limbs!
▶ Wear your personal protective equipment.
▶ Make sure that connections, valves, mechanical actuators and plug-in
connectors are easily accessible.
7.3.1 Installing the press module
WARNING
Falling down of the press module due to incomplete fastening or fastening with
insufficient stability!
Danger to life! Risk of injury! Damage to property!
▶ Assemble the press module only on a stable mounting surface. Pay attention to
the weight of the press module and the vibrations or movements of the pipeline.
▶ Only use mounting screws listed in the assembly drawing. Comply with the
specified tightening torque and screw material grade.
▶ Assemble the press module using a manual torque wrench.
▶ If necessary, pay attention to the tank penetration shown in the installation
drawing.
To install the press module, proceed as follows: