116/176 CANopen
Bosch Rexroth AG
, MIT: ID 40, 3 842 530 344/2014-05
9.20.4 “Resetting SLK” application
This example allows the SLK to be reset in the
DISCONNECTED
link state. The actual
link state here is not important.
No.
Action
COB
rd/wr
Index/
subindex
Data
1
Switch SLK to ERROR state
SDO
wr
2600/02
0x04
2
Wait until actual link state is ERROR
3
Switch SLK to DISCONNECTED state
SDO
wr
2600/02
0x02
4
Wait until actual link state is
DISCONNECTED
9.20.5 Handling “E00” errors
This example terminates direct data exchange with the MDT. The commanded link
state DISCONNECT fails and the SLK switches to the
ERROR
state.
No.
Action
COB
rd/wr
Index/
subindex
Data
1
Switch SLK to
DISCONNECTED
state
SDO
wr
2600/02
0x02
2
Wait until actual link state is
DISCONNECTED
or
ERROR
3
DISCONNECT unsuccessful, link state is now
ERROR
4
Switch SLK to
DISCONNECTED
state
SDO
wr
2600/02
0x02
5
Wait until actual link state is
DISCONNECTED
6
The SLK is now in the initial
DISCONNECTED
state and the application can
start over
PROOF COPy 1 | 20.05.2014 | FOR INTERNAL USE ONLy