Product description 17/84
3 842 540 399/2016-11, MIT: ID 200,
Bosch Rexroth AG
4.7 Displays and operating elements
Fig. 11:
BUS
Address
(High Nibble)
BUS
Address
(Low Nibble)
0
8
C
4
F
7
B
3
E
6
A
2
D
5
9
1
0
8
C
4
F
7
B
3
E
6
A
2
D
5
9
1
Displays and operating elements
4.7.1
LEDs
Designation
Function
Status description
CH1
CH2
“Operation”
Status display of the anten-
nas
LED lights up green if a command is active on the
antenna.
LED lights up yellow for approx. 1 second if a com-
mand has be executed successfully.
CH1
CH2
“Connect”
The connected antennas are
displayed
LED lights up green if an antenna is connected to
channel 1 or channel 2.
LED lights up red in the event of a configuration
error.
PWR/ERR
Status display of the ID
200/C-PDP
LED lights up green if the ID 200/C-PDP is con-
nected to an energy supply and the interface is
ready for operation.
LED lights up red in the event of a hardware error.
Profibus
Status display of the bus
LED is off until the first communication via the
PROFIBUS.
LED lights up green if the slave is in data exchange
status.
LED lights up red if there is a bus error and no data
exchange is possible.
Diag
Status display of the
data transmission
LED lights up
green
if a direct PC connection is in
place (section 8.1.1).
LED lights up
yellow
if a command has been sent
directly via RS232 Shell (see section 7.1.1 “Com-
mands in the web interface and the command
shell” ).
EN
GLISH