6
Technical Data
6.1
Technical Data for Intermittent and Continuous Operation
Due to technical development of the GTE gearboxes, the technical data re‐
garding permitted torques, torsional play and torsional strength could be im‐
proved.
These "new" technical data are valid for GTE gearboxes from man‐
ufacturing date 09W01 and are given in the following table.
To estimate the thermal permitted area of the gearboxes, a detailed display
format of the permitted nominal speed was chosen.
You will find the previous technical data in the chapter "Appendix".
Technical data for intermittent and continuous operation
Description
Symbol
Trans‐
mission
ratio
GTE040
GTE060
GTE080
GTE120
GTE160
Max. initial speed
7)
min
-1
n
in
, max
one-stage
i=3
18,000
13,000
7,000
6,500
6,500
i=4
18,000
13,000
7,000
6,500
6,500
i=5
18,000
13,000
7,000
6,500
6,500
i=8
18,000
13,000
7,000
6,500
6,500
two-stage
i=12
18,000
13,000
7,000
6,500
6,500
i=20
18,000
13,000
7,000
6,500
6,500
i=40
18,000
13,000
7,000
6,500
6,500
Max. initial torque
1) 9) 10) 11)
Nm
M
in
, max
one-stage
i=3
5.8
15
45.3
61.3
213.3
i=4
6
15.25
46
62
180
i=5
4.4
12.8
35.2
62.4
144
i=8
1.3
3.6
10
24
90
two-stage
i=12
2.7
5.8
16
34.7
106.7
i=20
1.6
3.5
9.6
20.8
64
i=40
0.7
1.6
4.4
9.2
28
Max. output speed
7)
min
-1
n
out
,
max
one-stage
i=3
6,000
4,333
2,333
2,166
2,166
i=4
4,500
3,250
1,750
1,625
1,625
i=5
3,600
2,600
1,400
1,300
1,300
i=8
2,250
1,625
875
812.5
812.5
two-stage
i=12
1,500
1,083
583
541.7
541.7
i=20
900
650
350
325
325
i=40
450
325
175
162.5
162.5
DOK-GEAR**-GTE********-PR06-EN-P
Rexroth GTE Planetary Gearboxes
Bosch Rexroth AG
31/85
Technical Data
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01